Product Code ::RXSOL-33-3302-230
Categories: RO Chemicals-33
Product Short Description: This is a reverse osmosis membrane treatment Antiscalant chemicals . It is highly concentrated polymer chemicals.
Product Description:

This is a reverse osmosis membrane treatment chemicals . It is  highly concentrated  polymer chemicals. Antiscalant RXSOL-33-3302-230 is a liquid antiscalant designed to inhibit scale in cellulose acetate and polyamide membrane separation systems. The formulation contains a 35% by weight solution of poly acid that has a tight molecular weight range of 2000. This product is designed for use in waters that do not have a high potential for colloidal and silt fouling of RO membrane surfaces (i.e. groundwater applications). Antiscalant RXSOL-33-3302-230  can be injected neat or diluted and a site‐specific dosage can be determined using  software program.

 

 



 

Product Application:

Performance:

Antiscalant RXSOL-33-3302-230 offers a variety of critical performance and application benefits:

  • Inhibits RO membrane scaling caused by the following:
Calcium Carbonate:  CaCO3
Calcium Sulfate:  CaSO4
Barium Sulfate: BaSO4
Strontium Sulfate: SrSO4
Calcium Fluoride: CaF2
  • Compatible with the polyamide and cellulose acetate RO membranes of the leading manufacturers.
Product Dose:
Antiscalant RXSOL-33-3302-230  performance is achieved when the chemical is injected downstream of multimedia filters and upstream of cartridge filters. For maximum effectiveness, Antiscalant RXSOL-33-3302-230 should be added prior to the static mixer or cartridge filter housing. For potable  the maximum dosage is 10 mg/L. Maximum dilution is 10% with RO permeate or DI water

Dosing Guidelines: 

The typical dosage range is between 2 to 5 ppm or Typical dosage range is between 2 and 6 mg/L.. A site‐specific dose can be determined using computer program. Like any injected chemical, over or underdosing may cause unnecessary membrane system fouling. Please contact the Avista customer service department for customized dosing instructions.

Dilution:

This product is formulated to be injected neat. However, if a dilution is required, use demineralized or RO permeate water. If neither of these is available, softened water may be substituted. The dilution for Vitec 1000 should not result in a solution strength of less than 10%. This guidelin will protect the effectiveness of the internal bacteriostat which inhibits bacterial growth in the drum and feed tank.Maximum dilution is temperature related as shown below.

Temperature, °C     Maximum Dilution, %
<30                                        12
30-35                                     25
>35                                        50

230  performance is achieved when the chemical is injected downstream of multimedia filters and upstream of cartridge filters. For maximum effectiveness, Antiscalant RXSOL-33-3302-230 should be added prior to the static mixer or cartridge filter housing. For potable  the maximum dosage is 10 mg/L. Maximum dilution is 10% with RO permeate or DI water

Dosing Guidelines: 

The typical dosage range is between 2 to 5 ppm or Typical dosage range is between 2 and 6 mg/L.. A site‐specific dose can be determined using computer program. Like any injected chemical, over or underdosing may cause unnecessary membrane system fouling. Please contact the Avista customer service department for customized dosing instructions.

Dilution:

This product is formulated to be injected neat. However, if a dilution is required, use demineralized or RO permeate water. If neither of these is available, softened water may be substituted. The dilution for Vitec 1000 should not result in a solution strength of less than 10%. This guidelin will protect the effectiveness of the internal bacteriostat which inhibits bacterial growth in the drum and feed tank.Maximum dilution is temperature related as shown below.

Temperature, °C     Maximum Dilution, %
<30                                        12
30-35                                     25
>35                                        50

Packaging and Storage:

Standard regional pack sizes are listed below and custom packaging can be provided worldwide. This product should be protected from freezing.

Specifications
Appearance: Yellow to liquid
pH (10% solution): 2.9

Specific Gravity@20oC:

 1.67 - 1.2

 Packing 30 Kgs, 230 Kgs drum.

 





 

Product Note:

RO antiscant

Scaling is caused in membranes because the level of hardness salts in the water becomes highly concentrated as it passes through the RO unit. In smaller units scale formation can be prevented by base exchange softening the make-up water but for larger systems that is very expensive. We have developed a range of easy to handle, cost effective RO Antiscalant which increase the solubility of the hardness salts so they remain in solution rather than forming scale on the membrane. Our cost effective RO antiscalants will inhibit a wide range of foulants including: calcium carbonate, calcium sulphate, barium sulphate, strontium sulphate, calcium fluoride, silica and iron.

RO Antiscalants are dosed directly to the RO feed water tank or feed water line (after pretreatment) at the recommended dosage of 1-3 mg/L and maximum dosage at 8mg/L, subject to inlet water quality and parameters is respect of Calcium Hardness, Iron, TDS, Alkalinity, pH and silica content. Maximum dilution should be 10% with RO or DI water for temperature less than 30 deg C. For higher temperature the dilution ratio can increase. 

Key Features and Benefits

  • Inhibit scale formation and effectively controls corrosion
  • Protects the membrane efficiently
  • Enhance the plant operation and equipments life span
  • Economical
  • Easy in usage and handling
 
Our RO Antiscalant (HIGH PH) is a super-threshold RO membrane antiscalant and antifoulant which is able to stabilize a wide range of supersaturated salt solutions, thereby preventing the precipitation on the membrane surface. 


It reduces the risk of scaling and eliminates the use of hazardous acids,resulting in efficient plant operation with highest possible conversion rate. 

It is a very effective antiscalant . It is also compatible with RO CHEMICALS series of coagulant and flocculants (polyelectrolytes). Our RO Antiscalant (HIGH PH) is effective in minimizing scaling in presence of foulants like Calcium Carbonate, Sulfate salts of Calcium, Barium, Strontium and Magnesium, Calcium Fluoride, Iron and Silica.

Key Features and Benefits

  • Effective scale inhibition 
  • Alkalinity builder 
  • High recovery rate 
  • Low Chemical dosage 
  • Cost Effective 
  • Effective Iron fouling control by sequestration 
  • Reduced frequency of membrane cleaning 
  • Compatible with all types of membranes 
  • Completely organic and biodegradable 


Application and Dosage
Our RO Antiscalant (HIGH PH) is dosed directly to the RO feed water tank or feed water line (after pretreatment) at the minimum recommended dosage of 1ppm and maximum dosage at 15ppm, subject to inlet water quality and parameters is respect of Calcium Hardness, Iron, TDS, Alkalinity, pH and silica content. 

In case of high iron content of about 0.5 to 1.0ppm, the dosing has to be increased by 10-15ppm for stabilizing Calcium. 

At about 10-15ppm dosage our RO Antiscalant (HIGH PH) is capable of fully inhibiting iron and calcium, and silica up to 166ppm. For higher silica content RXSOL ANTISCALANT should be used. 

Antiscalant RO                                   RXSOL-33-3302-025
Antiscalant C.I ALKA                          RXSOL-33-2034-025
Membrane Antiscalant ALKA 191T    RXSOL-33-3321-030 
Antiscalant ORG EV 2030                 RXSOL-33-3325-230
Antiscalant RXSOL ORG EV             RXSOL-33-3327

Hashtag: #MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant #Demulsifier #WaterlessHandCleaner #AirC
Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates