REVERSE OSMOSIS MEMBRANE CLEANER
RO membrane cleaners is specifically designed to remove iron fouling for silica. It also has effectiveness against calcium carbonate scaling. RXSOL-33-3304-025 performance can be enhanced by adding low / high ph cleaners to the cleaning solution although some minor ph correction may be necessary. It should always be used as recommended by the membrane manufacturer or equipment supplier, in respect to cleaning ph and temperature. it also contains organic dispersants that helps to break down colloidal clay deposits and imparts better efficacy to biocides by penetrating into films. it is specifically developed for removing iron, silica, metal silicates, metal oxides/hydroxides and other colloidal/particulate based foulants from ro membranes. It is also effective to remove calcium carbonate, calcium phosphate and silt.
As RXSOL-33-3304-025 is buffered, the cleaning solution will stabilise at pH 3.6.
High level of active substance.
Other Grades of Membrane cleaner :::
RXSOL-33-3322-025
RXSOL-33-3324-025
MSDS, Technical bulletine of MSDS are available on email request.
Treatment and Dosage Requirements
Cleaning solutions should be prepared with chlorine free product water to give a 4% w/w solution, or 1 kg of RXSOL-33-3304-025 to every 25kgs of water. As RXSOL-33-3304-025 is buffered the cleaning solution will stabilize at pH 3.6.
Deposition of fouling and scale directly affect the cleaning time In general practice to dissolve complete fouling 2 to 3 hours required . During chemical reaction between solution and deposition If the cleaning solution becomes brown to red in color it must be changed as the solution becomes completely non reactive.
On completion of cleaning process membrane should be clean with cupious amount of FRESH WATER till neutralisation of pH value of runing water.
For disposal of RXSOL-33-3304-025 cleaning solution should always be neutralized with alkali.
Liquid product for ease of use
Highly concentrated
Buffered to ensure pH control