BOILPLEX AT Hardness Control is specialized Boiler Water treatment product to KEEP Boiler water Clear and Clean SLUDGE FREE.
Boilplex AT is basically phosphates combination with synthetic polymers. Very easy to use, provides flexibility in system operation and control over the operation of the auxiliary and exhaust gas heaters on the boats. The tool is designed to maintain the cleanliness of the boiler at unstable as feedwater.
To be most effective to prevent corrosion and scaling using drug Boilplex AT the drug should be constantly adding to the boiler system with a dosing devices BWT Dosing System. Less preferable to use gravitational dosing device, because preparation can evaporate when the water returns into the tank cascade.
Regularly enter solutions drugs Boilplex AT with a dosing device BWT Dosing System in feedwater recirculation outlet below which returns cascading water in the tank. If there is no recirculation of feedwater, the drug should be submitted in suction tube feeding pump. When using gravity dispenser the drug should be fed to the point of feed water tank or in cascade. Drug supply line should be higher than normal water level (about 1 meter) and as close as possible to the fence of water nutrient pump. Boilplex AT to be dissolved in distilled water or condensate in the dispensing tank and gradually continuously fed for 24 hours, keeping the system demand. The daily dosage is depend on the volume of the system, the condensate quality and purity, as well as the quality and quantity of the feed water system. For standard operating systems the dosage Boilplex AT is about 1 liter a day.
Very large systems or in non-standard conditions will have a greater need for preparation. Many factors can affect the initial dose of the drug. The two most important factors - quality feedwater and the boiler. The recommended initial dose of 2.5 to 5 liters per tonne of water system. After the initial filling of the product during operation of the system on a daily basis should perform a test to adjust the dosage. Low quality feedwater demands increase quantities of preparation, as well as leaching of the polluted water from the boiler of the boiler due to the settling of particles on bottom of the boiler during system shutdown. This in turn entails the need for additional purging and increase the amount of drug.
The main objective of the program - to prevent fouling. The most effective way to fight c deposits is to use distilled water feed. Boilplex AT created for removing water hardness instability.
Blowdown
Purge procedure is necessary for the effectiveness of any treatment program and boiler watershall be in accordance recommendations manufacturer's instructions. Purging is required to remove the precipitate dissolved and suspended solids. Normal regular purging with sufficient neutral of conductivity 700 μmho. A higher rate of conductivity (above 700 μmho) frequency blowdown should be increased. Additionally, it is recommended to wash weekly collector or separator pair (if any) to reduce the accumulation of sludge.
Testing:
Dosage and frequency Boilplex AT controlled blowdown simple tests on the quality of the boiler water.Tests include checking parameters such as hydrate alkalinity, conductivity, phosphates, stiffness feedwater and condensate pH. For more information about the testing procedure, refer to Table control the amount and dosage Boilplex AT Control and Dosage Chart or contact representative of Rx Marine International.
CHARACTERISTICS :
BENEFITS